ATM X RAY - X

ATM X RAY - X

ATM X RAY–X - it is a new generation X-ray fluorescence spectrometer that solves a wide range of analytical tasks at a high level.
It is equipped with a high-performance semiconductor detector with electronic cooling, an ultrashort low-loss light path, a high-voltage excitation source, an independent cooling air supply channel, an automatic vacuum/helium switching system and an automatic rotary carousel for multiple images (with the option of rotating the sample). ATM X RAY-X provides high sensitivity, accuracy, intelligence and efficiency than similar models.
Main application: multi-element analysis of any material, including analysis of alloys, mining materials, detection of dangerous elements in food, feed, cosmetics, plastics.

The principle of operation

The principle of operation of the spectrometer is based on the analysis of the characteristic X-ray fluorescence spectra of radiation occurring in the measured sample under the influence of X-ray radiation.

The high-voltage power supply generator of the X-ray tube provides a stable supply voltage. X-ray tube radiation (primary X-ray radiation) irradiates the samples. The samples then emit fluorescent characteristic X-ray radiation. The fluorescent characteristic X-ray radiation of the sample is received by a semiconductor detector, amplified and fed into a multichannel pulse spectrometer compatible with a personal computer. Control of the spectrometer, selection of measurement modes and parameter control, processing of X-ray radiation spectra, obtaining measurement results in units of quantities characterizing the content of the component, or in intensities (relative intensities) of spectral lines of X-ray radiation is carried out using a computer using special programs.

 

General characteristics

Type: Energy Dispersive X-ray fluorescence Spectrometer

Model: ATM X RAY-X

Size: 650×565×390 mm;

Sample placement chamber size: Ø340×64(H) mm;

Weight: approx. 85 kg;

 

• Range of measured elements: from fluorine (F) to uranium (U) (depending on modification)

• Range of determination of the content of elements: ppm-99.99% (for different elements – different ranges)

• Simultaneous analysis of elements

• Measurement time: 60s - 200s

• Energy resolution of the detector: ≤129 eV

• Sample material: powder, solid, liquid

The measurement results in units of quantities characterizing the content of the component, or in the intensities (relative intensities) of spectral lines of X-ray radiation are carried out using a computer using special programs.


Configuration*

·      High-performance X-ray tube with ultra-thin window

·      Silicon Drift Detector SDD

·      Digital controller ADC

·      Advanced optical path

·      High signal-to-noise ratio preamplifier

·      Built-in high definition video camera

·      Automatic switching of collimators and filters

·      Carousel for multiple samples (with additional sample rotation system)

·      Automatic correction of the spectrum drift

·      Triple protection mode

·      Vacuum Pump with power Cable

·    USB cable, 2 pcs

·    USB 2.0 to RS485 Universal Cable

·    Suction bag

·    Sample spoon

·    Nylon tube

·    Film in a roll (0.08*220 m, 4 microns

·    Plastic pipette, (3 ml), 100 pcs

·    Reusable plastic cups for solid samples, 12 pcs (in box 17)

·    Disposable cups for liquid samples, 60 pcs (in box 63)

·    Holders for cups for liquid samples, 12 pcs

·    Steel rings for cups for liquid samples, 12 pcs

·    Instructions on the USB disk

 

*depending on the modification

Additional features

·           Single sample chamber and multi-sample chamber;

9/12/20-position carousel.

·           Switching between vacuum and helium by pressing a button;

To measure the contents of light elements in powders or liquids, you can use a switch between vacuuming (for powders) and helium supply (for liquids).

·           Universal intelligent testing system;

There is no need to choose different types of materials. Automatic detection of the material eliminates the human factor. This improves the accuracy of the analysis.

·      Detector protection and electromagnetic blocking;

The protective plate protects the detector window from damage due to improper operation. An electromagnetic lock prevents the lid from opening during analysis and radiation leakage.

·      Ultrashort optical path, ultra-low detection limit;

The ultrashort optical path and recommended filter combinations make it possible to determine the content of elements starting from F (fluorine), with a detection limit in light matrices for a number of elements of only 0.2 ppm.

·      Accurate quantitative and semi - quantitative analysis;

ROHS5.0, Composite analysis V4.0, Coating analysis, Intelligent analysis of an unknown sample using the FP method.